當(dāng)前位置:首頁 > 新聞中心不銹鋼消防箱的安裝要注意什么?

不銹鋼消防箱的安裝要注意什么,?

來源:http://m.n3462.cn/ 日期:2022-05-04

組合式消火栓箱可暗裝,,亦可明裝,與各種建筑內(nèi)裝修均可配套使用;箱體與箱門用活動(dòng)門軸連接,,根據(jù)用戶需要制成左開式,、右開式,箱體表面采用各種顏色的靜電噴塑,,箱內(nèi)水帶安置方式分為放置式,、掛架式、卷盤式三種,。
The combined fire hydrant box can be installed in the dark or in the open, and can be used together with various building interior decoration; The box body is connected with the box door with a movable door shaft, which is made into left open and right open according to the needs of users. The surface of the box body adopts electrostatic plastic spraying of various colors. The water hose in the box can be placed in three ways: placement type, hanger type and reel type.
1,、消火栓的啟閉閥門設(shè)置位置應(yīng)便于操作使用,閥門的中間距箱側(cè)面應(yīng)為140mm,,距箱后內(nèi)表面應(yīng)為100mm,,允許偏差±5mm。
1. The opening and closing valve of the fire hydrant shall be set at a position convenient for operation and use. The middle of the valve shall be 140mm from the side of the box, 100mm from the rear inner surface of the box, and the allowable deviation shall be ± 5mm.
2,、室內(nèi)消防箱的安裝應(yīng)平正,、牢固,暗裝的消防箱不應(yīng)破壞隔墻的耐火性能。
2. The installation of indoor fire box shall be flat and firm, and the concealed fire box shall not damage the fire resistance of the partition wall.
川消
3,、箱體安裝的垂直度允許偏差為±3mm,。
3. The allowable deviation of the perpendicularity of the box installation is ± 3mm.
4、不銹鋼消防箱門的開啟不應(yīng)小于120°,。
4. The opening of stainless steel fire box door shall not be less than 120 °.
5,、安裝消火栓水龍帶,水龍帶與消防水槍和快速接頭綁扎好后,,應(yīng)根據(jù)箱內(nèi)構(gòu)造將水龍帶放置,。
5. Install the fire hydrant hose. After the hose is bound with the fire water gun and quick connector, place the hose according to the structure in the box.
6、雙向開門消防箱應(yīng)有耐火等級(jí)應(yīng)符合設(shè)計(jì)要求,,當(dāng)設(shè)計(jì)沒有要求時(shí)應(yīng)少滿足1h耐火極限的要求,。
6. The fire resistance rating of the two-way open fire box shall meet the design requirements. If there is no design requirement, it shall meet the requirements of at least 1H fire resistance limit.
7、消防箱門上應(yīng)用紅色字體注明“消火栓”字樣,。
7. The words "fire hydrant" shall be marked on the door of the fire box in red font.